A.O. Smith BFM - 120, BFM - 100 manual Troubleshooting insufficient hot water

Models: BFM - 100 BFM - 120

1 74
Download 74 pages 2.7 Kb
Page 59
Image 59

is

11.3 Troubleshooting: insufficient hot water

Warning

Maintenance may only be performed by a qualified service and maintenance engineer.

Insufficient hot water

Symptom

Cause

Solution

Remark

 

 

 

 

Insufficient hot water

Water temperature

Set the control thermostat (7.5 "Control thermostat") to a higher

 

 

setting (Tset) is too low

value

 

 

Hot water supply is

1.

Reduce hot water consumption and give the appliance time to

If this error persists, check whether the high-limit thermostat is

 

used up

 

heat up.

switching.

 

 

2.

If this error persists, check whether the high-limit thermostat is

 

 

 

 

switching.

 

 

 

 

If this is the case, check that the circulation and/or top to bottom

 

 

 

 

circulation pump are working.

 

 

 

 

 

 

Instruction manual BFM

59

Page 59
Image 59
A.O. Smith BFM - 120 manual Troubleshooting insufficient hot water, Symptom Cause Solution Remark Insufficient hot water