12

ACER G24

4. Assembly and Disassembly Procedures

Go to cover page

4.1 Assembly procedures:

Connect the cable between power board(P802)

S1 and interface board (P301)

Connect the function key cable into interface board(P303)

Connect the cable between power board(P803)and inverter board (Cn001)

Connect the FFC cable into interface board

P301

P802

Use a Phillips-head screwdriver screwed the

S4 No.1~4 screws till that interface board and bracket chassis base firmly attached.

(No1~4 screw size=M3x6; Torque=9~10KGFxCM).

3

2

1

4

P303

CN01

P803

Take the key function cable out from the hole

S5 shown as photo

Take a bracket chassis base on a protective

S2 cushion and stick an insulator on the specific position, take a power board and turn it over. Then, put it on the specific positions of bracket chassis base.

Use a Phillips-head screwdriver screwed the

S3 No.1~5 screws till that power board and bracket chassis base firmly attached.(No1~4 screw size=M3x6; No5 screw size=M4x8; Torque=9~10KGFxCM).

4

1

2

Fix the function key cable with a PVC tape

Turn over the bracket chassis base then fix the

S6 inverter board

Use a Phillips-head screwdriver screwed the No.1~4 screws till that inverter board and bracket chassis base firmly attached.

(No1~4 screw size=M3x6; Torque=9~10KGFxCM).

2

1

4

3

3

5