8

1 System overview

Weight

The table below lists the weight of individual components used in deployment of this system in third-party racks.

Item

Weight in Kg

Weight in lbs

 

 

 

Fully configured

13 Kg

28.6 lbs

system

 

 

 

 

 

Rack mount kit

3.1 Kg

6.82 lbs

 

 

 

CPU and fan sink

0.35 Kg

0.77 lbs

 

 

 

Hard disk drive

1Kg

2.2 lbs

 

 

 

Power supply module

1.3 Kg

2.86 lbs

 

 

 

Floppy disk drive

0.16 Kg

0.35 lbs

 

 

 

CD-ROM drive

0.3 Kg

0.66 lbs

 

 

 

PCI card

0.04 ~ 0.4 Kg

0.09 ~ 0.88 lbs

 

 

 

Power consumption

The server power supply is rated for a maximum 220W DC output. Maximum input AC power consumption is approximately _____.

Using 110V AC power, a fully loaded system can consume up to 2.80A

Using 220V AC power, a fully loaded system can consume up to 1.40A

Deployment of ultra-dense 1U servers represent a significant power requirement. A simple formula to calculate server power requirements for an installation is:

(Number of servers) x (307W) = maximum power requirements for servers

Page 18