5. Troubleshooting (continued)

5.2 Nothing display on screen (screen is black, color of LED is blue)continued

ACER H233H

 

25

Go to cover page

Continue

Check the 5V power supply for

P301 pin 4,5,6.

NG

Check the I304 pin2 if voltage is 3.3V

OK

Check the I305 pin2 if voltage is 1.2V

OK

NG

NG

Proceed "Checking the DC/DC converter

circuit" section.

Proceed "Checking the DC/DC converter

circuit" section.

 

 

Check the I301 pin2 if

 

 

 

 

Failure Point

 

 

 

NG

 

OK

 

voltage is 5V

 

 

 

1) FB301 is open..

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check if the voltage

 

 

 

 

 

 

 

between I301 pin2 and

 

 

 

 

 

 

 

pin3 is above -0.7V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

Failure Point

I301 is failure.

Check the input voltage level whether was changed when

pressed function keys on the P309 pin1

 

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check if the voltage on I308 pin 108 that is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from 3.3V to 0V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the P307 all LVDS signals.

 

 

 

 

 

 

 

 

Failure Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I308 is failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failure Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Printed wire broke between P307 and

 

 

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I308 LVDS signals.

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2) I308 is failure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failure Point

1)The LVDS cable broke between P307 and LCD module.

2)LCD module is failure.

Failure Point

1)Printed wire broke between P309 pin 1 and I308 pin 108.

Page 26
Image 26
Acer RB23WABAS service manual Circuit section