28

 

ACER H233H

 

 

 

Go to cover page

5. Troubleshooting (continued)

5.5 Abnormal screen (For DVI and the same for HDMI)

Check the DVI video signal from computer input

on P303 of DVI connector.

NG

OK

Failure Point

1)No DVI video signals output from host computer, check computer.

2)DVI Video signal cable disconnection.

Check the DVI input video signals on I308 pin

12,13,14,15,16,17,18,19 respectively that

differential input voltage is 150 to 1200mV, and

input commond mode voltage is 3.3V.

NG

OK

Failure Point

In the case of the DVI_RX0+/- signal. (A DVI_RX1+/-, DVI_RX2+/- and DVI_RXC+/- signal is the same path, too.)

1)Printed wire broke between P303 pin 17, 18 and I308 pin 12. 13.

2)Video cable is failure.

3)R350, R355 open.

Check all LVDS signals being output to P307

from I308?

NG

OK

Failure Point

Printed wire broke between I308 and P303.

Proceed "Checking the resolution change IC

movement" section.

Page 29
Image 29
Acer RB23WABAS service manual Go to cover