X1161/X1261/X1161A/X1161N/X110/H5360 Condential 3-3
No Symptom Procedure
4No Image
- Ensure the Signal Cable and Source work
(If you connect multiple sources at the same time, use the
"Source" button switch)
- Ensure all connectors are securely connected and aren’t
broken
- Check Main Board
- Check DMD Board
- Check DMD Chip
- Check Color Wheel
- Check Engine Module
5Mechanical Noise
- Check Color Wheel
- Check Fan Module
6Line Bar/Line Defect
- Check if the Main Board and the DMD Board are
assembled properly
- Check Main Board
- Check DMD Board
- Check DMD Chip
7Image Flicker
- Do "Reset (All data)" of the OSD Menu
- Ensure that the signal cables and source are work as well
- Check Lamp Driver and waveform
- Check Lamp Module
- Check Color Wheel
- Check Photo Sensor and clean Photo Sensor
- Check DMD Board
- Check Main Board
8Color Abnormal
- Do "Reset (All data)" of the OSD Menu
- Adjust Color Wheel Index
- Check Main Board
- Check DMD Board
- Check Color Wheel