(1) Calibration pattern should be in full screen

 

mode.

 

(2) Please press "Power", "Left", "Left" and "Menu"

 

buttons sequentially to get into Service Mode.

 

(3) Choose "Analog Settings", press “Menu” button

 

to access "Video Calibration for" correction in

 

Service Mode. Choose “Exit” to leave the

 

Service Mode.

Check pattern

- Test signal: 480i

 

- Test pattern: In focus II or 64 grey RGBW

 

* After finishing ADC adjustment, check 64 gray

 

RGBW pattern.

Inspection item

- Color saturation

Criteria

- There should not have any lack of RGBW. The

 

color should appear normal and sort in right order.

-Color levels should be sufficient and normal. (the unidentified color levels on both left and right sides should not over 8 color levels.)

3.G Sensor Calibration

-Please put the Projector on a horizontal surface.

-Please press "Power", "Left", "Left" and "Menu" buttons sequentially to get into Service Mode.

-Choose and access "G Sensor Calibration" for correction.

InFocus II

/ 64 gray RGBW

 

X1161/X1261/X1161A/X1161N/X110/H5360

Confidential

4-

Page 64
Image 64
Acer X110 service manual Sensor Calibration