USB eModule Error Messages

Message Displayed

Description

 

 

Warning!

This message is displayed when a non-bootable USB device is enumerated and

Unsupported USB

disabled by the BIOS.

device found and

 

disabled!

 

 

 

Warning! Port 60h/

This message is displayed to indicate that port 60h/64h emulation mode cannot be

64h emulation is not

enabled for this USB host controller. This condition occurs if USB KBC emulation

supported by this

option is set for non-SMI mode.

USB Host Controller!

 

 

 

Warning! EHCI

This message is displayed to indicate that EHCI controller is disabled because of

controller disabled. It

incorrect data structure. This condition occur if the USB host controller needs 64-bit

requires 64bit data

data structure while the USB is ported with 32-bit data structure.

support in the BIOS.

 

 

 

SMBIOS eModule Error Messages

Message Displayed

Description

 

 

Not enough space in

This message is displayed when the size of the SMBIOS data exceeds the

Runtime area!!.

available SMBIOS runtime storage size.

SMBIOS data will not

 

be available.

 

 

 

CPU eModule Error Messages

Message Displayed

Description

 

 

Warning! This system

This message is displayed when the power requirements of the board do not match

board does not

the power requirement of the CPU.

support the power

 

requirements of the

 

installed processor.

 

The processor will

 

be run at a reduced

 

frequency, which will

 

impact system

 

performance. area!!.

 

SMBIOS data will not

 

be available.

 

 

 

MPS Table (Multi-processor) eModule Error Messages

Message Displayed

Description

 

 

Insufficient Runtime

This message is displayed when there is not enough space in the 0F000h runtime

space for MPS data!

area for creating MPS table.

System may operate

 

in PIC or Non-MPS

 

mode.

 

 

 

Chapter 4

65

Page 73
Image 73