GM Historic (OBD I) Diagnostics

View Data

The View Data function allows the user to view the vehicle Parameter Identification Data (PIDs) in real time. As the PCM monitors PIDs, they are simultaneously transmitted to the scan tool. The PIDs are continuously updated at the PCM’s rate.

In addition to reading codes, View Data is the most useful diagnostic function for isolating the cause of a vehicle operation problem. Viewing data is also used for observing sensor data and the ON/OFF state of switches, solenoids, and relays.

View Data can be performed with the ignition key On-Engine Off or Running.

!! WARNING

Never operate the tool while driving. Have another person assist with the operation of the tool.

 

Select View Data from the GM

 

Function List and press ENTER. If a

 

Select Group screen does not appear,

 

skip the Multiple Group section and

 

continue.

5

Multiple Group Vehicles

Some vehicles display a Select Group screen for viewing data. In these cases, only one group of data can be viewed at a time.

GM Function List

?

1)Read

Codes

 

2)Erase

Codes

[

` 3)View

Data

~

Select

Group

 

?

Engine

Group

1

 

Engine

Group

2

 

` Engine

Group

3

~

Select the type of data to view. Refer to “Viewing Data” on page 3-11 for Entire or Custom Data Lists.

After making a selection, press ENTER to establish a communication link.

Use the UP/DOWN arrow keys to scroll through the PIDs.

A Vehicle Data List header marks the beginning.

Select Data To View? 1)Entire Data List

`2)Custom Data List

~

Custom

Data List

Codes

Present

Yes

1ST

GEAR SW

ON[

A/F

RATIO

18.8~

Change the selection of Custom Data List parameters at any time by pressing the BACK key. This returns to the Custom Data List selection screen.