SECTION VII

PHASE 6 OPL SYSTEM DIAGNOSTICS

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and
THE GAS SUPPLY or THE STEAM SUPPL Y BEFORE ANY COVERS or
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS
FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY
EQUIPMENT per OSHA (Occupational Safety and Health Administration)
STANDARDS.
ALL major circuits, including door, microprocessor temperature sensor, heat and motor circuits are monitored.
The Phase 6 OPL microprocessor controller (computer) will inform the user, via the L.E.D. (light emitting diode)
display of certain failure codes, along with indicators both in L.E.D. display and at the output of each relay (and
door switch circuit) to easily identify failures.

A. DIAGNOSTIC (L.E.D. [light emitting diode] DISPLAY) FAILURE CODES

1. SAIL SWITCH FAIL- This routine will prevent start up on the machine unless the sail switch is in the
correct position. If the sail switch is closed prior to start up the display will read “SAIL SWITCH FAIL”
along with an audio indication.
2. No AIRFLOW- If the sail switch opens during cycle operation the display will read “No AIRFLOW”
along with an audio indication. The machine will continue to run with no heat for three (3) minutes or until
the temperature drops below 100º F (38º C). Upon failure the machine will shut down and display “No
AIRFLOW” with an audio indication.
3. bURNER SAFETY FAIL- Routine monitors the temperature above the burner. If the burner hi-limit
switch opens the display will read “bURNER SAFETY FAIL.” The machine will run with no heat for
three (3) minutes or until the temperature drops below 100º F (38º C). Upon failure the machine will shut
down and display “bURNER SAFETY FAIL” with an audio indication.
4. dRUM SAFETY FAIL- This routine monitors the tumbler (basket) temperature if the tumbler (basket)
hi-limit switch opens prior or during the cycle while the heat was on the machine will display “dRUM
SAFETY FAIL.” The machine will continue to run with no heat for three (3) minutes or until the temperature
drops below 100º F (38º C). Upon failure the machine will shut down and display “dRUM SAFETY
FAIL” with an audio indication.
5. No HEAT- This routine monitors the burner ignition. If the burner mis-ignites (does not light) the HSI
(Hot Surface Ignition) module will check to see of the microprocessor program has any retries left. The
standard retry count is two (2). If the module notices that there are retries left it will purge for one (1)
minute then try to ignite the burner again. The HSI module will try this for a total of three (3) times or until
there are no retries left. If the burner does not ignite after three (3) attempts the L.E.D. (light emitting
diode) display will display the error code “no heat” with an audio indication. When this occurs the
machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C).
IMPORTANT: For other countries, such as Australia, the retry count may not apply due to local
approvals.