I.Display reads “Temp Sensor Failure Check Temp Sensor Fuse.” Dryer Sensor Circuit Failure...
1.Check
2.Faulty microprocessor controller (computer) temperature sensor probe.
3.Open circuit in either one (1) of two (2) wires leading from the sensor probe to the computer...
a.Connection at sensor bracket assembly connector.
b.Connection at computer harness connector.
4.Faulty microprocessor controller (computer).
J.Dryer does not start. Display reads “main door” or “lint door” with an audio indication...
1.Main door is open.
2.Lint drawer is open.
3.Faulty main door or lint door switch.
4.Open circuit in either main door or lint drawer switch harnesses.
5.Faulty 24 VAC transformer.
K.There is excessive vibration coming from the tumbler (basket)...
1.Tumbler (basket) is out of adjustment.
2.Drive shaft or idler shaft is out of alignment.
3.Faulty pillow block bearing.
4.Faulty tumbler (basket) wheel.
5.Drive motor and shaft not aligned.