LTPH-UM-1109-01, Issue 1

Installation

 

 

INSTALLATION

Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC.

H2TU-C-231

HLU-

 

HiGain

431

 

LINE

UNIT

CO Shelf

PairGain

Figure 2. Installing the H2TU-C-231 List 2 into a Shelf

When installing an H2TU-C 231 in a chassis, be sure to wear an antistatic wrist strap. Avoid touching components on the circuit board.

To comply with the intrabuilding wiring requirements of GR-1089 CORE, Section 4.5.9, the shields of the ABAM-type cables that connect the H2TU-C-231 List 2 DSX-1 output ports to the cross-connect panel must be grounded at both ends.

1Align the H2TU-C with the enclosure slot guides and slide the unit in. Push the unit back until it touches the backplane card-edge connector and the retaining latch on the front panel opens.

2Place your thumbs on the front panel and push the H2TU-C into the slot guides until the retaining latch closes.

This indicates that the card is properly seated.

H2TU-C-231 List 2

January 9, 2002

7