LTPH-UM-1109-01, Issue 1

Provisioning

 

 

Table 5 describes the Standard Config menu options and Table 6 on page 18 describes the ADC Config menu options. Selections in bold type indicate factory default settings.

Table 5. H2TU-C-231 List 2 Standard Config Menu Options

Standard Config

Front-Panel

 

 

Display

Selection

Description

Menu Options

Code

 

 

 

 

 

 

 

 

 

Loopback

LBTO

NONE

Disables automatic time-out cancellation of all loopbacks.

Timeout

 

20

Sets automatic cancellation of all loopbacks to 20 minutes after initiation.

 

 

 

 

60

Sets automatic cancellation of all loopbacks to 60 minutes after initiation.

 

 

120

Sets automatic cancellation of all loopbacks to 120 minutes after initiation.

 

 

8 hr

Sets automatic cancellation of all loopbacks to 8 hours after initiation.

 

 

24 hr

Sets automatic cancellation of all loopbacks to 24 hours after initiation.

 

 

 

 

Loop Attenuation

LATT

0 through

Determines the maximum loop attenuation before an alarm is declared. The

Threshold

 

40 dB

loop attenuation threshold can only be set through the maintenance screens.

 

 

 

Zero disables the alarm.

 

 

35 dB

Default value.

 

 

 

 

Margin Threshold

MARG

0 to 15 dB

Determines the minimum allowable margin below which a system alarm can

 

 

 

occur. The Margin (Alarm) Threshold can only be set through the

 

 

 

maintenance screens. Zero disables the alarm.

 

 

4 dB

Default value.

 

 

 

 

DS1 Frame

FRMG

AUTO

Configures the HiGain HDSL2 system to operate in an auto-framing (AUTO)

Formatting

 

 

mode in which it continuously searches the input DS1 bit stream for a valid

 

 

 

SF or ESF frame pattern. Both line and path performance parameters are

 

 

 

maintained. Unframed payloads will cause the ES-P and SES-P counters to

 

 

 

increment.

 

 

SF

Configures the HiGain HDSL2 system to search for the SF framing pattern at

 

 

 

its DS1 input.

 

 

ESF

Configures the HiGain HDSL2 system to search for the ESF framing pattern at

 

 

 

its DS1 input.

 

 

UNFR

Configures the HiGain HDSL2 system to operate in an unframed mode. This

 

 

 

mode disables the auto framing process and forces the system to function as

 

 

 

a transparent bit pipe. Only line parameters are considered when monitoring

 

 

 

DS1 performance.

 

 

 

 

DS1 Line Coding

DS1

AUTO

The H2TU-C-231 and H2TU-R monitor the incoming DS1 bit streams for the

See “DS1 Line

 

 

B8ZS code. If the H2TU-R detects this code, the H2TU-C enters B8ZS output

 

 

mode. The H2TU-C reverts back to AMI output mode if no B8ZS codes are

Coding (DS1)

 

 

 

 

received at the H2TU-R input for 5 seconds. Similarly, when the H2TU-C

Option” on

 

 

page 19.

 

 

detects the B8ZS code, the H2TU-R enters B8ZS mode and returns to AMI

 

 

mode if no B8ZS code is received at the H2TU-C input for 5 seconds.

 

 

 

 

 

B8ZS

Places both the H2TU-C-231 and H2TU-R into B8ZS mode.

 

 

AMI

Places both the H2TU-C-231 and H2TU-R into AMI mode.

 

 

 

 

H2TU-C

EQL

EXT

Disables the H2TU-C internal equalizer, allowing connection of external

Equalization

 

 

equalizer hardware.

See “H2TU-C

 

0

Sets the Equalizer to DSX-1 for 0 to 132 feet.

Equalization

 

133

Sets the Equalizer to DSX-1 for 133 to 265 feet.

(EQL) Option.” on

 

page 20.)

 

266

Sets the Equalizer to DSX-1 for 266 to 398 feet.

 

 

399

Sets the Equalizer to DSX-1 for 399 to 532 feet.

 

 

533

Sets the Equalizer to DSX-1 for 533 to 655 feet.

 

 

 

 

 

 

 

Continued

H2TU-C-231 List 2

January 9, 2002

17