LTPH-UM-1109-01, Issue 1Provisioning

Table 6. H2TU-C-231 List 2 ADC Config Menu Options (Continued)

ADC Config Menu

Front Panel

 

 

Display

Selection

Description

Options

Code

 

 

 

 

 

 

 

 

 

DS1 BER

DBER

ENA

Enables the fixed 24-hour DS1 BER threshold.

Threshold

 

DIS

Prevents the generation of a system alarm due to DS1 BER.

See “DS1 BER

 

 

 

 

(DBER) Option”

 

 

 

on page 21.

 

 

 

 

 

 

 

HDSL2 BER

HBER

1E-6

System alarm relay contact closes and the Status LED flashes red when the

Threshold

 

 

Block Error Rate exceeds 10-6.

See “HDSL2 BER

 

1E-7

System alarm relay contact closes and the Status LED flashes red when BER

Threshold (HBER)

 

 

exceeds 10-7.

Option” on

 

NONE

Prevents generation of a system alarm due to BER.

page 21 and

 

“System Alarm

 

 

 

Output Pins” on

 

 

 

page 58.

 

 

 

 

 

 

 

Special Loopback

SPLB

GNLB

Configures the HiGain HDSL2 system to respond to the generic inband

Mode

 

 

loopback codes.

 

 

A1LB and

Configures the HiGain HDSL2 system to respond to the inband loopback

 

 

A2LB

codes of the Westell addressable repeater.

 

 

A3LB

Configures the HiGain HDSL2 system to respond to the inband loopback

 

 

 

codes of the Wescom addressable repeater.

 

 

A4LB

Configures the HiGain HDSL2 system to respond to the inband loopback

 

 

 

codes of the Wescom Mod 1 addressable repeater.

 

 

A5LB

Configures the HiGain HDSL2 system to respond to the inband loopback

 

 

 

codes of the Westell Mod 1 addressable repeater.

 

 

 

 

SmartJack

LPBK

ENA

Enables the HiGain HDSL2 system to recognize all inband SmartJack (SMJK)

Loopback

 

 

loopback commands.

 

 

DIS

Configures the HiGain HDSL2 system to ignore all inband SmartJack

 

 

 

loopback commands.

 

 

 

 

Minor Alarm

ALM

ENA

Enables the generation of the output alarm on pins 20 and 21 when a system

 

 

 

alarm condition occurs.

 

 

DIS

Disables the generation of the output alarm on pins 20 and 21 when a system

 

 

 

alarm condition occurs.

 

 

 

 

Remote

RDA

ENA

Enables a remote DS1 LOS condition at the input to the H2TU-R to generate

Disconnect Alarm

 

 

an LOS alarm. AIS or LOS (depending on ALMP) is sent towards the network.

 

 

DIS

Prevents a remote DS1 LOS condition at the input to the H2TU-R from

 

 

 

causing an LOS alarm. The front-panel Status LED still flashes red and the

 

 

 

ALRM RLOS message displays, but the alarm relay contacts do not close and

 

 

 

LOS is sent towards the network from the H2TU-C instead of AIS.

DS1 Line Coding (DS1) Option. The DS1 line code option should always be set to conform to the type of DS1 service (AMI or B8ZS) being provided by the HiGain HDSL2 system. The Auto mode, which can adapt to either AMI or B8ZS, should only be used in applications that require it (such as when HiGain HDSL2 acts as a standby circuit to DS1 circuits whose line codes are not known or may be both AMI and B8ZS). This is because the Auto mode induces one BPV in the DS1 bit stream whenever it switches from AMI to B8ZS. The Auto mode allows both the H2TU-C and the H2TU-R to set its DS1 output code to that which is being received at the distant end DS1 input. This forces the input and the output codes in each direction of transmission to be identical.

H2TU-C-231 List 2

January 9, 2002

19