Provisioning | |
|
|
Resetting to Factory Default Values
All user options for the
1Press the SEL pushbutton for 6 seconds until the following message appears:
DFLT NO
2Press the SEL pushbutton while the DFLT NO message is displayed.
The message changes to DFLT YES indicating the factory default values are now in effect and the display returns to the normal mode.
To terminate the DFLT mode without setting the factory default values, do one of the following:
•Press the MODE pushbutton to return to the normal display mode.
•Wait 30 seconds for the unit to return to the normal display mode.
Displaying System Parameter Settings
To scroll through the current settings of all system parameters, press the MODE pushbutton for 3 or more seconds. The
•Software version number
•List number
•Type of frame pattern received from the
•Line code of the signal received from the
•All
•Loop attenuation threshold setting
•Margin alarm threshold setting
Disabling an Alarm
If the system is in a Minor alarm state, the alarm relay can be disengaged by pressing the SEL pushbutton. This activates the Alarm Cutoff (ACO) indication. For more information about alarms, see “System Alarms” on page 40.
Loopback Modes
See “Loopback Operation” on page 43 for instructions on using the MODE and SEL pushbuttons to activate loopbacks.
10 | January 9, 2002 |