ProvisioningLTPH-UM-1109-01, Issue 1

Table 5. H2TU-C-231 List 2 Standard Config Menu Options (Continued)

Standard Config

Front-Panel

 

 

Display

Selection

Description

Menu Options

Code

 

 

 

 

 

 

 

 

 

H2TU-R Line

RLBO

 

Sets the DS1 receive level output toward the Customer Interface (CI). H2TU-R

Buildout

 

 

Line Buildout can only be set through the maintenance screens.

 

 

0 dB

Sets the DS1 RLBO level toward the CI to 0 dB.

 

 

-7.5 dB

Sets the DS1 RLBO level toward the CI to -7.5 dB.

 

 

-15.0 dB

Sets the DS1 RLBO level toward the CI to -15.0 dB.

 

 

 

 

Alarm Pattern

ALMP

AIS

Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports

See “Alarm

 

 

for LOSW and DS1 LOS. See Figure 26 on page 42 for LOS/AIS response

 

 

priorities.

Pattern (ALMP)

 

 

Option” on

 

LOS

Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports

page 20.

 

 

for LOSW and DS1 LOS.

 

 

 

 

H2TU-R TLOS

TLOS

ENA

Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input.

Loopback

 

 

See Figure 26 on page 42 for LOS/AIS response priorities.

 

 

DIS

Disables Transmit Loss of Signal (TLOS) logic loopback.

 

 

 

 

Network

NLBP

AIS

Enables the H2TU-R to transmit an AIS towards CI for any network loopback.

Loopback Pattern

 

 

See Figure 26 on page 42 for LOS/AIS response priorities.

 

 

LOS

Enables the H2TU-R to transmit an LOS towards CI for any network loopback.

 

 

 

 

Power Back Off -

PBOC

DEF

Configures the power output levels of the H2TU-R customer unit toward the

Customer

 

 

network to comply with the Default template as defined in Section 6.1.4.2 of

See “Power Back

 

 

ANSI T1/E1.4.

Off (PBON and

 

ENH

Configures the power output levels of the H2TU-R customer unit toward the

PBOC) Options”

 

 

network to comply with the Enhanced template as defined in Section 6.1.4.2

on page 20.

 

 

of ANSI T1/E1.4.

 

 

 

 

Power Back Off -

PBON

DEF

Configures the power output levels of the H2TU-C-231 network unit toward

Network

 

 

the customer to comply with the Default template as defined in Section

See “Power Back

 

 

6.1.4.2 of ANSI T1/E1.4.

Off (PBON and

 

ENH

Configures the power output levels of the H2TU-C-231 network unit toward

PBOC) Options”

 

 

the customer to comply with the Enhanced template as defined in Section

on page 20.

 

 

6.1.4.2 of ANSI T1/E1.4.

 

 

 

 

Table 6. H2TU-C-231 List 2 ADC Config Menu Options

ADC Config Menu

Front Panel

 

 

Display

Selection

Description

Options

Code

 

 

 

 

 

 

 

 

 

Line Power Feed

PWRF

OFF

Disables powering to the HDSL2 pair.

 

 

ON

Keeps the HDSL2 line voltage at nominal -180 Vdc.

 

 

 

 

Remote

RTPV

ENA

Enables remote provisioning.

Provisioning

 

DIS

Disables remote provisioning.

 

 

 

 

 

 

Bipolar Violation

BPVT

ENA

Enables BPVs and HDSL2 CRC errors at the DS1 input to be converted into

Transparency

 

 

DS1 BPVs at the DS1 output at the distant end. This makes HiGain HDSL2

See “Bipolar

 

 

transparent to BPVs.

Violation

 

DIS

Disables BPV Transparency.

Transparency

 

 

 

(BPVT) Option”

 

 

 

on page 20.

 

 

 

 

 

 

 

 

 

 

Continued

18

January 9, 2002

H2TU-C-231 List 2