Monitoring System Activity and PerformanceLTPH-UM-1109-01, Issue 1
Table 10. Acronyms Used on the HDSL2 Performance History Screens
Error Acronym | Description |
|
|
CV | Code Violation |
|
|
| Total count of HDSL2 CRC errors |
| |
ES | Errored Seconds |
|
|
| Seconds with HDSL2 CRC ≥ | 1 or LOSW ≥ | 1 |
SES | Severely Errored Seconds |
|
|
| Seconds with HDSL2 CRC ≥ | 50 or LOSW ≥ | 1 |
UAS | Unavailable Seconds |
|
|
| Based on 10 contiguous SES occurrences |
| |
LOSWS | Loss of Sync Word Second |
|
|
| Seconds with LOSW ≥ 1 |
|
|
USING THE PERFORMANCE SCREENS TO VIEW ALARM DATA
To access the alarm history screens:
1Press P to select the Performance screen.
2Press the SPACEBAR to select an interface
3Press the SPACEBAR until Alarm History is selected, then press ENTER .
4Press N or P to page through the alarm history screens.
5Press L to clear the selected alarm history screen.
32 | January 9, 2002 |