Provisioning | |
|
|
DS1 BER (DBER) Option. The DS1 BER alarm occurs when any of the DS1 or
Table 7.
Parameter | Threshold Count |
|
|
133,400 | |
648 | |
100 | |
10 | |
|
|
HDSL2 BER Threshold (HBER) Option. The HBER option permits the monitoring of loop integrity and reporting of alarms when excessive errors are detected. The PM primitive used for this purpose is the CRC checksum performed on the HDSL2 frame for both directions of transmission. It is, therefore, called a block error rate rather than the bit error rate associated with the DS1 interface. The CRC errors and counts are displayed on the Monitor screen for both the
•HBER option =
•HBER option =
Once initiated, the HBER alarm clears when the CRC count drops below the selected threshold. Selecting NONE inhibits this alarm.
January 9, 2002 | 21 |