Testing | |
|
|
TESTING
This section provides information about
SYSTEM ALARMS
Table 15 summarizes all possible HDSL2 system alarms in order of priority as they appear on the front panel. When multiple alarms occur, the
Table 15.
Alarm | Description | To Inhibit | |
Message (a) | |||
PWR FEED | Power Feed Short | A short exists between the Tip and Ring of | Cannot be inhibited. |
SHRT (b) |
| the HDSL2 pair. |
|
PWR FEED | Power Feed Ground | The HDSL2 loop is grounded. | Cannot be inhibited. |
GND (b) |
|
|
|
PWR FEED | Power Feed Open | A line power open condition exists. | Cannot be inhibited. |
OPEN (b) |
|
|
|
LOSW (c) | Loss of Sync Word (d) | The HDSL2 loop has lost synchronization. | Cannot be inhibited. |
LLOS (c) | Line (Unit) Loss of | Loss of the | Cannot be inhibited. |
| Signal |
|
|
RLOS (c) | Remote (Unit) Loss of Loss of the |
| Signal |
Disable the RDA (Remote Disconnect Alarm) option. The
LAIS | Line Alarm Indication | Indicates an AIS (unframed all ones) | Cannot be inhibited. |
| Signal | pattern is being received at the |
|
|
| DS1 input port. |
|
|
|
|
|
RAIS | Remote Alarm | Indicates an AIS (unframed all ones) | Cannot be inhibited. |
| Indication Signal | pattern is being received at the |
|
|
| DS1 input port. |
|
|
|
|
|
LRAI | Line | Indicates an RAI alarm (yellow) from the | Cannot be inhibited. |
| Alarm Indication at the | CPE with an |
|
| unit or network. RAI signal is transmitted |
| |
| does not have errors.) | towards the network. |
|
|
|
|
|
RRAI | Remote | Indicates an RAI alarm (yellow) from the | Cannot be inhibited. |
| Alarm Indication at the | CPE with errors from the line unit or |
|
| network. |
| |
| errors.) |
|
|