LTPH-UM-1109-01, Issue 1

Monitoring System Activity and Performance

 

 

Alarm History at the HDSL2 Interface

The HDSL2 Alarm History screens report alarms at the H2TU-C and the H2TU-R. Figure 23 shows the H2TU-C HDSL2 alarm history and Table 12 below describes the alarms that are reported at the H2TU-C-231 or H2TU-R.

Monitor Performance Event Log Config Inventory Report Rlogon Help

H2TU-C HDSL2 Alarm History

-----------------------------------------------------------------------------

Alarm

First

Last

Status

Count

LOSW

 

 

OK

0

MAL

 

 

OK

0

LA

 

 

OK

0

HBER

09/01/01 00:37

09/01/01 00:45

OK

7

SHORT

 

 

OK

0

GND

 

 

OK

0

OPEN

 

 

OK

0

Press: C(l)ear Alarm History

------------------------------------------------------------------------------

Use <Space>

to

cycle through

Interface :

H2TU-C HDSL2

 

choices and

<Enter> to

view

Statistics :

Alarm History

 

ID: xxxx--

xxxx

--xxxx--

xxxx

09/01/2001 12:30:01

H2TU-C

System: Alarm

Figure 23. H2TU-C HDSL2 Alarm History Screen

 

 

Table 12. HDSL2 Alarm Descriptions

 

 

 

Screen Alarm

Front-Panel Alarm

Description

 

HDSL2 ALARMS at the H2TU-C and H2TU-R

 

 

 

LOSW

LOSW

Loss of Sync Word—The HDSL2 loop has lost synchronization.

MAL

xxx-MAL

Margin—The margin on the HDSL2 loop has dropped below the minimum threshold value

 

 

set for the system. (xxx denotes either TUC or TUR.)

LA

xxx-LA

Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value

 

 

set for the HDSL2 loop attenuation threshold. (xxx denotes either TUC or TUR.)

HBER

xxx-HBER

Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of

 

 

10-6or 10- 7. (xxx denotes either TUC or TUR.)

HDSL2 ALARMS at the H2TU-C only

 

 

 

 

SHORT

PWR FEED SHRT

Indicates a short between the Tip and Ring of the HDSL2 pair.

GND

PWR FEED GND

The HDSL2 loop is grounded.

OPEN

PWR FEED OPEN

Indicates a line power open condition.

 

 

 

H2TU-C-231 List 2

January 9, 2002

35