CHAPTER 4

 

Using terminal commands

APPLIES TO

A720, A720B, A723

DESCRIPTION

Sets/returns the input storing and sampling intervals.

PARAMETERS

storage represents the time (in seconds) elapsed between two

 

slots stored in the internal memory, while samples represents the

 

numbers of samples used to build the average that will be stored.

RETURNS

The interval and rate.

REMARKS

The default storage is 900 (15 minutes) and samples is 3 (3 sam-

 

ples per quarter of an hour).

REMOTE

Yes, SET only.

EXAMPLE

SLOT 900 3

 

193 SLOT 0

 

#

 

SLOT

 

193 SLOT 900 3 0

 

#

 

Note: The A720B base station needs only the rate. For consis-

 

tency, however, it accepts both parameters and discards the

 

one it doesn’t need.

33

COMMAND

PMP

APPLIES TO

A720, A720B, A723

DESCRIPTION

Sets/returns the node’s Power Management Parameters (switches

 

on/off the battery charge).

PARAMETERS

The lower (switch on) and the higher limit (switch off), both in volts

 

x 10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for

 

7.2 Volts) for switch off.

RETURNS

The lower (switch off) and the higher limit (switch on), both in volts

 

x 10.

REMARKS

GET/SET.

REMOTE

Yes, SET only.

EXAMPLE

PMP 65 72

 

193 PMP 0

 

#

Page 33
Image 33
Adcom A720, A723 manual Pmp