API Guide
601355 Rev A API Functions 2-1005
Functins
VSID_RETRY_LIMIT (VST_RETRY_LIMIT) The number of times the API software retries
for command status from VolServ before
returning a time-out to the client software for
MultiMount commands. VSID_RETRY_LIMIT
is not applicable when the API software
executes in asynchronous mode. The default
retry limit is 3.
VSID_STATUS_WAIT_FLAG
(VST_STATUS_WAIT_FLAG) A flag indicating whether the API software
waits for final status from VolServ (or
times-out) for MultiMount commands. Valid
options are VSE_TRUE (API software waits for
final status) and VSE_FALSE (API software
does not wait for final status). Also determines
whether the API software operates in
synchronous mode (VSE_TRUE) or in
asynchronous mode (VSE_FALSE). The
default VSID_STATUS_WAIT_FLAG value is
VSE_TRUE.
VSID_TIMEOUT_VALUE (VST_TIME_OUT) The amount of time (in seconds) the API
software waits for status from VolServ before
returning a time-out to the client software. The
default time-out value is 120 seconds.
VSID_USER_FIELD (VST_USER_FIELD) The value to put in USER_FIELD for
MultiMount commands. USER_FIELD is a
16-character field provided for user
information. Information entered in this field is
echoed back to the user in every status
message returned for MultiMount commands.
Neither the API software nor VolServ uses
USER_FIELD.
Parameter Type Description