Aga Ranges DC6 (FFD) Technical Data, Hotplate, Natural Gas, L.H.F, R.H.F, R.H.R, L.H.R, Centre

Models: DC6 (FFD)

1 60
Download 60 pages 34.31 Kb
Page 4
Image 4
TECHNICAL DATA

TECHNICAL DATA

HOTPLATE

 

 

 

 

 

 

NATURAL GAS

L.H.F.

R.H.F.

R.H.R.

L.H.R.

CENTRE

CENTRE

 

BURNER TYPE

WOK

 

 

 

FRONT

REAR

ULTRA-RAPID RAPID

RAPID

SEMI-RAPID SEMI-RAPID ULTRA-RAPID

MAXIMUM HEAT

5.85 kW

3.22 kW

3.22 kW

1.91 kW

1.91 kW

5 kW

INPUT

 

 

 

 

 

 

BTU’s/hr

20,000

11,000

11,000

6,500

6,500

17,000

INJECTOR MARKING

 

 

 

 

 

 

MAIN

80Hi

155

155

118

118

200

SECONDARY

2 x 1.30

-

-

-

-

-

PRESSURE POINT POSITION: REAR RH SIDE OF HOTPLATE

 

 

PRESSURE SETTING:

4” W.G.

 

 

 

 

 

BURNER IGNITION: H.T. SPARK

 

 

 

 

 

PROPANE

L.H.F.

R.H.F.

R.H.R.

L.H.R.

CENTRE

CENTRE

 

BURNER TYPE

WOK

 

 

 

FRONT

REAR

ULTRA-RAPID RAPID

RAPID

SEMI-RAPID SEMI-RAPID ULTRA-RAPID

MAXIMUM HEAT

4.8 kW

3.0 kW

3.0 kW

1.75 kW

1.75 kW

4.0 kW

INPUT

 

 

 

 

 

 

BTU’s/hr

16,500

10,250

10,250

6000

6000

13,500

INJECTOR MARKING

 

 

 

 

 

 

MAIN

46

85

85

65

65

110

SECONDARY

2 x 66

-

-

-

-

-

PRESSURE POINT POSITION: REAR RH SIDE OF HOTPLATE

 

 

PRESSURE SETTING: 10” W.G.

 

 

 

 

 

BURNER IGNITION: H.T. SPARK

 

 

 

 

 

ELECTRIC GRILL AND OVENS

 

 

WEIGHT OF APPLIANCE: 220 kg

TOP OVEN POWER RATING - 1.45 kW BROILER ELEMENT - POWER RATING 2.45 kW SLOW COOKING OVEN - POWER RATING 1.0 kW LOWER OVEN (FAN) - 2.2 kW

240 VOLT 60 Hz SINGLE PHASE

The data plaque is located on a pull out plate - lower front of appliance (See Fig. 10, Page 22).

TYPICAL SECTION VIEW OF FLAMES:

LHF HOTPLATE BURNER

RHF & RHR HOTPLATE

 

 

BURNER

15/16”

 

 

3/4”

 

9/16”

LHR & CF HOTPLATE BURNER

7/8” 1/2”

CR HOTPLATE BURNER

9/16”

4

Page 4
Image 4
Aga Ranges DC6 (FFD) Technical Data, Hotplate, Natural Gas, L.H.F, R.H.F, R.H.R, L.H.R, Centre, Burner Type, Front, Rear