LOCATION

LOCATION

This appliance must be installed on 1/8” thick Commercial Grade Vinyl composition floor finishing materials or equivalent.

Combustible side wall clearance above the hotplate shall be greater than 3”.

Surfaces over the top of the range must not be closer than 28” and must not exceed 13” in depth.

The vent slots in the back of the top plate (or shroud) must not be obstructed.

Note: It is essential that the supply cable is routed away from any hot surfaces i.e. hot flue pipes.

In the interests of safety, due consideration must be given to the protection of the electric cable to the unit.

Remember than an excess of cable length is required for the possible withdrawal of the range.

A electrical socket type 14-30R must be provided within 5 feet of the left hand side of the range and be accessible for disconnection.

THE INSTALLATION MUST CONFORM WITH THE NATIONAL ELECTRIC CODE.

Disconnect the electrical supply before servicing the appliance. Electrical hook-up must be done by a licenced electrician.

An easily accessible manual shut off gas valve must be fitted before the metal flexi gas line supply to the range. DO NOT fit valve behind the range.

Any opening in the wall behind the appliance and in the floor under the appliance must be sealed.

If the range must be installed beside a refrigerator, it is important for proper air circulation that there be at least 5” (175mm) of space between the two appliances.