PRESSURE TESTING

POSITION OF GAS VALVE ON WALL (locate in shaded areas)

IMPORTANT: THE GAS SUPPLY CONNECTION AT THE WALL MUST NOT PROJECT OUT FROM THE WALL BY MORE THAN 1 3/4” (44mm), SO THAT IT DOES NOT INTERFERE WITH THE BACK OF THE COOKER.

Fig. 4

DESN 512640

PRESSURE TESTING

The maximum gas inlet pressure to the appliance must not exceed 10” w.g. for NG and 14” for L.P. Gas. The minimum gas inlet pressure at the appliance must not be less than 5” w.g. Natural Gas and 11” w.g. L.P. Gas to enable the correct manifold pressure to be obtained.

NOTE: The regulator is pre-set for either N.G. or L.P. Gas.

Use the small hotplate burner injector as the pressure test point.

For Natural Gas manifold pressure is 4” w.g.

For L.P.G. (Propane Only) manifold pressure 10” w.g.

Access to the gas regulator is as follows:

a)Remove pan supports and all control knobs.

b)Remove four chrome buttons and the four plate retaining screws (2 each side).

c)Remove left hand and centre shroud from the control panel to gain access to the fixing screws. Remove two screws from control panel (one from left hand hole and one from centre hole). (See Fig. 3).

d)Pull top plate forwards slightly and lift up at front. Support top plate and disconnect wiring to the two neons. Remove top plate.

e)Lay the top plate on its top face, suitably protected.