4-Wire Conduit Installation

Read all instructions before installing or using this appliance.

Installation Instructions

Save these instructions for future reference.

4-Wire Conduit Installation

Fitting a 3-Wire Power Cord

Disconnect the supplied power cord from the

Disconnect the supplied power cord from the

terminal block and ground post. Keep the terminal

terminal block and ground post. Keep the terminal

block parts; you will need them. Remove the strain

block parts; you will need them. Remove the strain

relief clamp from the power cord and remove

relief clamp from the power cord and remove

the power cord and strain relief clamp from the

the power cord and strain relief clamp from the

mounting bracket.

mounting bracket. Discard the strain relief clamp.

The range is shipped with reducer plates to give a 1

NOTE: Do not install the power cord without a

1/8’’ diameter opening for conduit connection. Find

strain relief - use the clamp supplied with the

the reducer plates in the miscellaneous parts pack

cord.

and fit them to the mounting bracket.

 

 

Fit the new strain relief device to the mounting

 

bracket by removing the two clamping screws,

Fit a squeeze connector (not supplied with the

feeding the two halves (ears first) through the hole

range), to your conduit. Insert the conduit through

in the mounting bracket and loosely refitting the

the reducer plates on the mounting bracket. Allow

screws. Insert the power cord through the strain

enough slack to easily attach the wires to the

relief device but do not tighten the device yet.

terminal block.

A Ground strap is supplied

 

NOTE: Do not install the conduit without a squeeze

 

in the miscellaneous parts

 

connector.

pack.

ground strap. (grey)

 

Fit the Ground strap to the ground and center

 

terminal of the connector block - see the figure.

Fit the wires to the ground post and terminal block.

NOTE: Make sure the wires are completely inserted into the terminals and secure connections are made.

Secure the squeeze connector in place in the bracket by tightening the squeeze connector screws.

Refit the electrical connection cover.