Table A-3. Replacement Parts

REF. DESIG.

MODEL NO,

PART NO.

DESCRIPTION

A7

All

5060-2854

Opt. 002 Interface Board

C1,2

All

0180-0230

fxd elect. 1∝F 20% 50V

C3

All

0180-2825

fxd elect. 22∝F 50V

C4

All

0160-4835

fxd cer. 0.1∝F 10% 50V

C5

All

0160-4554

fxd cer. 0.0∝F 20% 50V

C6

All

0160-4835

fxd cer. 0.1∝F l0% 50V

C7

All

0160-4554

fxd cer. 0.0∝F 20% 50V

C8,9

All

0180-0230

fxd elect. 1∝F 20% 50V

C10

All

0180-2825

fxd elect. 22∝F 50V

C11

All

0160-4801

fxd cer. 100pf 5% l00V

C12,13

All

0160-5422

fxd cer. 0.047∝F 20% 50V

C14

All

0160-4801

fxd cer. 100pfF 5% l00V

C15

All

0160-5422

fxd cer. 0.047∝F 20% 50V

C16

All

0160-5422

fxd cer. 0.047∝F 20% 50V

C17,18

All

0180-0230

fxd elect. 1∝F 20% 50V

C19

All

0180-2825

fxd elect. 22∝F 50V

C20-22

6010

0160-0128

fxd cer. 2.2∝F 20% 50V

C20-22

6011A, 6012B

0160-0122

fxd cer. 2.2∝F 20% 50V

CR1-4

All

1901-0050

switching 80V 200ma

CR5-10

All

1901-0327

pwr. rect. 300V 40A

CR11-14

All

1901-0033

gen. prp. 180V 200ma

CR15

All

1901-0327

zener 9.09V 10% PD=1.5W

CR16,17

All

 

NOT USED

CR18,19

All

1901-0050

switching 80V 200ma

CR20

All

1901-0033

gen. prp. 180V 200ma

CR21,22

All

1901-0050

switching 80V 200ma

CR23

All

1901-0033

gen. prp. 180V 200ma

CR24,25

All

1901-0050

switching 80V 200ma

CR26-29

All

1901-0033

gen. prp. 180V 200ma

CR30

All

1901-0327

zener 9.09V 10% PD=1.5W

K1,2

All

0490-1418

relay 250ma 28V,5V –coil 3VA

L1-3

All

9170-1223

core shielding bead

Q1,2

All

1854-0823

NPN SI PD=300mW FT=200MHZ

R1-3

All

0683-2015

fxd. film 200 5% 1/4W

R4

All

0683-3925

fxd. film 3.9K 5% 1/4W

R5

All

0683-2035

fxd. film 20K 5% 1/4W

R6

All

0683-3035

fxd. film 30K 5% 1/4W

R7

All

0683-6225

fxd. film 6.2K 5% 1/4W

R8,9

All

0683-2035

fxd. film 20K 5% 1/4W

R10

All

0683-1035

fxd. film 10K 5% 1/4W

R11

All

0683-5125

fxd. film 5.1K 5% 1/4W

R12

All

0757-0984

fxd. film 10 1% 1/2W

R13

All

0683-1615

fxd. film 160 5% 1/4W

R14

All

0683-4715

fxd. film 410 5% 1/4W

R15,16

All

0683-1235

fxd. film 12K 5% 1/4W

R17

All

0686-1525

fxd. film 1.5K 5% 1/4W

R18

All

0683-1535

fxd. film 15K 5% 1/4W

R19

All

0683-4715

fxd. film 470 5% 1/4W

R20,21

All

0683-1235

fxd. film 12K 5% 1/4W

111

Page 111
Image 111
Agilent Technologies 6015A, 6010a, 6011A, 6012B service manual Table A-3. Replacement Parts, 111

6015A, 6012B, 6011A, 6010a specifications

Agilent Technologies, a leader in the field of measurement and analysis, offers a suite of instruments within its 6010 and 6011 series, specifically the 6010A, 6011A, 6012B, and 6015A models. These devices are designed to meet the needs of various industries, including healthcare, environmental monitoring, and materials testing.

The Agilent 6010A is a high-performance spectrometer known for its precision and versatility. It utilizes advanced optical technologies to provide exceptional wavelength accuracy and resolution. This model is particularly useful in laboratories where reliable data is critical, offering a wide spectral range and effective noise reduction features. Its user-friendly interface simplifies complex analyses, making it suitable for both seasoned professionals and newcomers.

Following closely, the Agilent 6011A is recognized for its robust capabilities in laboratory environments. This device incorporates advanced signal processing techniques, enabling high-throughput measurements without compromising on quality. The 6011A is ideal for real-time monitoring applications, ensuring that users can make informed decisions based on accurate, timely data. Its comprehensive software suite is designed to enhance data analysis, allowing for seamless integration with existing laboratory workflows.

The 6012B variant enhances the functionality further by introducing additional features tailored for specific applications. With a focus on flexibility, the 6012B supports multiple measurement modes, including direct and differential detection. This model excels in complex measurements, allowing for greater analytical depth and insights. The built-in calibration options ensure consistent performance, making it a reliable choice for various research and development tasks.

Lastly, the Agilent 6015A model stands out with its leading-edge technology, designed for the most demanding applications. It boasts enhanced sensitivity and an improved dynamic range, making it perfect for trace analysis in challenging environmental samples. The 6015A’s advanced reporting tools provide detailed analytics, helping scientists and researchers interpret results efficiently. Its compact design also makes it suitable for laboratory spaces with limited room, without sacrificing performance.

Together, these models showcase Agilent Technologies' commitment to delivering high-quality, innovative solutions that empower users to achieve their analytical goals effectively and efficiently. Whether in a research, clinical, or industrial setting, the 6010A, 6011A, 6012B, and 6015A continue to set standards in precision instrumentation.