To increase the speed at which your switch matrix operates, refer to the table below to determine which four relays, when connected, will be on the same drive lines.

a.Refer to Figure 2-6to wire your relays into the arbitrary positions of OPEN and CLOSE.

b.Refer to the section “Example Speed Calculation” on page 4-74for an explanation on calculating and minimizing overall switching time.

Switching speed is a function of pulse widths, sensing delays, the state of the chosen channels, the sequence of relays driven and the power supply recovery time. Pulse widths, sensing delays, and which channels are opened or closed are determined by the user, and cannot be predicted here.

The channel number must be preceded by the driver card number. Channels connected to driver card 1 would be numbered 100 to 130; card 2, 200 to 230; card 3, 300 to 330, and so forth up to card 800 to 830. All of these channels are set with the drive enabled.

Table 2-1 Relay Drive Sequence

Drive Line

Connector Locator

Channel List

 

 

 

1

J1, J2, J3, J4

00, 01, 02, 03

 

 

 

2

J5, J6, J7, J8

04, 05, 06, 07

 

 

 

3

J9, J10, J11, J12

08, 09, 10, 11

 

 

 

4

J13, J14, J15, J16

12, 13, 14, 15

 

 

 

5

J17, J18, J19, J20

16, 17, 18, 19

 

 

 

6

J21, J22, J23, J24

20, 21, 22, 23

 

 

 

7

J25, J26, J27, J28

24, 25, 26, 27

 

 

 

8

J29, J30, J31

28, 29, 30

 

 

 

NOTE

The maxium Power Supply Recovery Time should only be required when

 

driving multiple external driver boards with longer interconnect cables. A

 

significant switching speed advantage can be realized if this value is reduced

 

from the 200 msec default. See the command called “TRIGger” on

 

page 4-62and the “Example Speed Calculation” on page 4-74.

 

 