Creating and Downloading User-Data Files

User File Data (Bit/Binary) Downloads (E4438C and E8267D)

Line

Code Description—Download User File Data

8Send the user file data stored in the array (databuffer) to the signal generator.

iwrite() sends the data specified in databuffer to the signal generator (session identifier specified in id).

The third argument of iwrite(), bytesToSend, contains the length of the databuffer in bytes. In this example, it is 2000.

The fourth argument of iwrite(), 0, means there is no END of file indicator in the data.

In many programming languages, there are two methods to send SCPI commands and data:

Method 1 where the program stops the data download when it encounters the first zero (END indicator) in the data.

Method 2 where the program sends a fixed number of bytes and ignores any zeros in the data. This is the method used in our program.

For your programming language, you must find and use the equivalent of method two. Otherwise you may only achieve a partial download of the user file data.

9Send the terminating carriage (\n) as the last byte of the waveform data.

iwrite() writes the data “\n” to the signal generator (session identifier specified in id).

The third argument of iwrite(), 1, sends one byte to the signal generator.

The fourth argument of iwrite(), 1, is the END of file indicator, which the program uses to terminate the data download.

To verify the user file data download, see “Command for Bit File Downloads” on page 299 and “Commands for Binary File Downloads” on page 300.

Command for Bit File Downloads

Because the signal generator adds a 10- byte file header during a bit file download, you must use the SCPI command shown in Table 8- 3. If you FTP or copy the file for the initial download, the signal generator does not add the 10- byte file header, and it does recognize the data in the file (no data in the transmitted signal).

Bit files enable you to control how many bits in the file the signal generator modulates onto the signal. Even with this file type, the signal generator requires that all data be contained within bytes. For more information on bit files, see “Bit File Type Data” on page 288.

Table 8-3 Bit File Type SCPI Commands

Type

Command Syntax

 

 

Command

:MEM:DATA:BIT <"file_name">,<bit_count>,<block_data>

 

This downloads the file to the signal generator.

 

 

Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide

299

Page 309
Image 309
Agilent Technologies N5181A/82A, N5183A MXG, E8663B manual Command for Bit File Downloads, Bit File Type Scpi Commands

N5183A, N5183A MXG, E8663B, N5181A/82A specifications

Agilent Technologies is renowned for its innovative solutions in electronic test and measurement equipment. Among its offerings are several signal generators including the N5181A, N5182A, E8663B, and N5183A MXG. These models are distinguished not only by their performance but also by their versatility across various applications in communications, aerospace, and electronics.

The Agilent N5181A and N5182A, part of the MXG family, are highly versatile signal generators known for their exceptional frequency performance and flexibility. The N5181A operates from 100 kHz to 6 GHz, while the N5182A extends that range up to 12 GHz. They provide high fidelity signals with low phase noise, making them ideal for the development and testing of RF components and systems. These generators support a wide variety of modulation formats, including AM, FM, PM, and pulse modulation, catering to diverse application needs.

The E8663B, meanwhile, is designed for the range of 250 kHz to 3 GHz and is also recognized for its high-performance features. Its built-in capabilities for modulation make it effective for testing wireless devices, ensuring that signals can be simulated accurately in both laboratory and field environments. It is especially beneficial for users requiring a straightforward and efficient solution with high reliability.

The N5183A MXG signal generator enhances the lineup with frequency coverage up to 6 GHz and advanced capabilities. It integrates various modulation capabilities while ensuring high signal integrity. Its architecture is tailored for both production test environments and research applications, providing users with the flexibility to adapt to changing testing requirements.

Common characteristics across these models include a user-friendly interface that simplifies configuration and operation. They are often equipped with LAN and USB interfaces for easy remote control and integration into automated test systems. The robustness of these generators allows them to perform reliably in challenging environments, making them essential tools in laboratories, manufacturing floors, and field testing scenarios.

In summary, Agilent's signal generators, including the N5181A, N5182A, E8663B, and N5183A MXG, represent a blend of advanced technology, flexibility, and precision. These instruments are vital in facilitating the evolution of cutting-edge communication technologies, ensuring that designers and engineers can confidently meet the demands of modern electronics.