Configuration of Installation Screen cont.:

O

N

M

I J KL

I)Comms Time, allows you to adjust the time that a panel can remain in communication. The call will terminate after the time has expired. (min 10, max 300 seconds) Keypad Errors sets the maximum number of times an incorrect code can be attempted before the entry panel shuts down. (max 9) Keypad Lock- out for, sets the amount of time that the keypad will be shut down. (min 10, max 300 sec) Once the keypad has been locked out an error / warning message will be displayed on the panel.

J)Camera 5VDC / Relay 3, allows you to activate the CN5 connector. Not recommended to use, contact Aiphone for additional information.

K)Loudspeaker Volume, adjusts the speaker volume heard out at the entrance panel.

L)Microphone Volume, adjusts the microphone volume heard at the tenant.

M)Call to Door Panel, allows for a phone to call the entrance panel, provided it has the Passcode.

Panel rings for adjusts the amount of time that the entrance panel will ring when called. (min 0, max 45 sec)

A 4 digit Passcode must be used to turn on this feature.

N)Call from Door Panel, controls the calls coming from the door panel. Prefix of Telecoms Provider is used if the telecom provider has a unique prefix. Handset rings for sets the time that the entrance panel will ring a telephone number. (min 10, max 300 sec.)

O)Clocks Change displays the dates

specified in the Installation screen under the Update tab in the Summer / Winter Clock Change menu.