IP Router Configuration
7750 SR OS Router Configuration Guide Page 99
The multiplier specifies the number of consecutive BFD messages that must be missed from the peer
before the BFD session state is changed to down and the upper level protocols (OSPF, IS-IS or PIM)
is notified of the fault.
The no form of the command removes BFD from the router interface regardless of the IGP.
Default no bfd
Parameters transmit-interval — Sets the transmit interval, in milliseconds, for the BFD session.
Values 100 — 100000
Default 100
receive receive-interval — Sets the receive interval, in milliseconds, for the BFD session.
Values 100 — 100000
Default 100
multiplier multiplier — Set the multiplier for the BFD session.
Values 3 — 20
Default 3
cflowd
Syntax cflowd {acl | interface}
no cflowd
Context config>router>interface ip-int-name
Description This command enables cflowd to collect traffic flow samples through a router for analysis.
cdflowd is used for network planning and traffic engineering, capacity planning, security, and
application, as well as user profiling, performance monitoring, and SLA measurement. When cflowd
is enabled at the interface level, all packets forwarded by the interface are subjected to analysis
according to the cflowd configuration.
Default no cflowd
Parameters ACL — cflowd policy associated with a filter.
interface — cflowd policy associated with an IP interface.
local-proxy-arpSyntax [no] local-proxy-arp
Context config>router>interface ip-int-name
Description This command enables local proxy ARP on the interface.
Default no local-proxy-arp