42
Using Web Browser Control
Only alphanumeric characters, ., _, -, or @ are available to set an E-mail address.Note
Select the conditions for sending the second E-mail.
ERROR: an error is detected by self-diagnosis.
LAMP RUNTIME: remaining lamp service time has reached the value set in the field.
INPUT AIR TEMPERATURE: intake air temperature has reached the value set in the field.
Enter the E-mail address to which the
E-mail is to be sent when two E-mail
addresses are going to be used. Do not
enter it when the second E-mail
address is not going to be used.
Check these boxes when E-mail is to
be sent periodically to two E-mail
addresses. E-mail will be sent at the
times and on the days checked.
Button to update settings
E-mail set up page (Continuing)Authentication server set up page
The authentication server is set on this page when POP authentication or SMTP authentication is required for mail transmissions.
Click [Network set up], then [Authentication set up] to display the authentication server set up page.
For SMTP authentication, change the
authentication method to use, as desired.
Change the authentication method as desired.
Enter the POP server name.
Available input characters:
alphanumeric characters (A - Z, a - z,
0 - 9), hyphen (-) period (.)
Enter the user name for the SMTP or
POP server.
Enter the password for the SMTP or
POP server.
Button to update settings
Enter the SMTP server port number.
Enter the POP server port number.