Metering, Chapter 7

7.2METER SETUP

The VU meter scaling, headroom, decay time, and peak hold time are all adjustable using the Display menus. The Display button is in the lower left group of buttons beneath the meter display.

Scaling determines whether the meter range is -72 dB to 0 (Normal; this is the default) or -2.0 to +2.0 (Fine).

Headroom sets the headroom amount for the Fine VU meter mode (it does not affect the normal mode) by letting you specify what value the 0 dB marking represents. The value ranges from 2 to 22 dB, in 1 dB steps (default = 15 dB).

Decay sets the time for a meter segment to turn off after the signal goes below that level, with a range of 1 to 99. Each step represents 5 milliseconds, with higher numbers standing for longer decays. The maximum decay of 99 means a segment will hold for 500 ms. (1/2 second). Default = 10.

Peak hold time sets how long peaks will be held when the meters are in momentary Peak Hold mode, from 1 to 99. Each step represents 250 milliseconds, with higher numbers standing for longer holds. The maximum decay of 99 means a segment will hold for 24.75 seconds after level has fallen. Default = 8

Operation

You press…

You see…

Enter VU meter scaling

Display button

Display says VU Meter

setup

 

Scale

Edit VU meter scaling

Up/Down buttons

Display shows Normal

 

 

or Fine scaling

Enter VU meter

Display button again

Display says Fine

headroom page

 

Headroom

Edit VU meter headroom

Keypad or Up/Down

Display shows amount of

 

buttons to choose the

Fine headroom in dB

 

headroom amount

 

Enter VU meter decay

Display button again

Display says VU Decay

page

 

 

Edit VU meter decay

Keypad or Up/Down

Display shows amount of

 

buttons to choose the

meter decay time

 

amount of decay

 

Enter VU peak hold page

Display button again

Display says VU Peak

 

 

Hold

Edit VU peak hold

Keypad or Up/Down

Display shows amount of

 

buttons to choose the

peak hold time

 

peak hold time

 

7-2