Operation
Cycle Execution
To start the selected cycle, press the Start key. If the selected cycle number is not in the computer memory, the display will show “NCYC.” If this happens, select another cycle. Otherwise, the display will now show the first step. For example, if the display reads “HL0l,” “HL” represents a hot fill to low level, and “01” indicates that this is the first step of
the cycle.
As the cycle proceeds, the display will show the function being executed, the step number, and the cycle number selected. Pressing the Edit Cycle key while the cycle is running will cause the display to show the remaining cycle time in minutes. Pressing this key again will return the display to normal.
To begin the cycle at any step other than the first step, press the Advance key to advance through the cycle to the desired starting point. (The Advance key is enabled at the factory and can be disabled at the laundry site.) Then press the Start key.
It is possible to skip to the next step in a cycle, with the exception of a drain step: Drain steps must be allowed time to complete.
When the display shows the step desired to begin the cycle, press the Start key.
If the door is not locked, the display will indicate “CLOSE” and “DOOR.” If this occurs, be sure the door is closed and locked and press the Start key again.
If the LED indicator lights for the computer outputs indicate that one or more outputs are activated but the
As water fills the
●When the indicator dot in the last digit on the right is lit, the low water level has been reached.
●When the dot in the
●When the dot over the third digit from the right has been lit, high level has been reached.
The cycle will continue until its completion. Then the display will read “DONE.”
Test Cycle
Cycle number 01 is a test cycle used to analyze
Step 01 in cycle number 01 is a cold fill to low level. This step is designed to give not quite enough time to complete a fill, causing the display to read “FILL.” Press the Start key to continue the fill, and the test cycle will proceed.
Step 02 in the test cycle is a drain step. Again, the time allotted is shorter than it would be in a normal cycle. The display will read “EMTY.” To proceed, press the Start key.
The steps in the test cycle are relatively short with the exception of steps 3 and 21. These can be shortened by pressing the Advance key to go on to the next step.
The operator may skip to any next step in the cycle with the exception of a drain step: Drain steps must be allowed to complete. To skip forward in the test cycle, press the Advance key.
NOTE: The Advance feature may be disabled. See Prompting the
20 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232090 |