x600 Layer 3 Gigabit Ethernet Switch Installation Guide

System Fault LED is Steadily On

If the system FAULT LED is steadily on, a problem has occurred in the switch. Do the following:

ˆReset the switch by disconnecting and reconnecting the AC power cord.

ˆIf the FAULT LED remains ON, download a new version of the switch’s operating system software. For instructions, refer to the AlliedWare PlusTM Operating System Software Reference Guide.

Note

If the FAULT LED remains steadily on, contact Allied Telesis Technical Support for assistance. See “Contacting Allied Telesis” on page 12.