i n s t a l l a t i o n
water connections
water requirements
one (1) cold water inlet - drinking quality
one (1) treated water inlet: | 3/4" g |
line pressure: | 30 to 90 psi |
| 2.8 to 6.2 bar |
REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS
water drain:
Flush the water line at the installation site.
install water intake filters (provided) [see Figure 1] before connecting the oven to the water supply.
Backflow Prevention — The equipment must be installed with adequate backflow protection to comply with applicable federal, state, and local codes.
PiPe sealing taPe (teFlon®) must be used at all connection Points. The use of a pipe sealing compound is not recommended.
Figure 1
Install water intake filter
WATER INLET
3/4" G
HAND SPRAYER VALVE REQUIRES ADDITIONAL WATER SUPPLY
TANK
one suggested
method of installation
Water Filter
note:
unions or FleXible lines should be used to allow For oven movement when being serviced or cleaning
is needed.
reFer to Figure 1 above For ProPer intaKe locations.
Incoming cold water connection to filter or treatment system
Treated cold water
to backflow preventer to treated connection on oven
system for combitherm®. The combiguard™
The combiguard™ Bws Blended water system utilizes reverse osmosis to remove more than 97% of the total dissolved solids from water which can be precisely blended with filtered and treated water.
CombiGuard™
CT Express INSTALLATION MANUAL • 14..