Alto-Shaam 4.10esi i n s t a l l a t i o n, site INSTALLATION, installation codes & Standards

Models: 4.10esi 4.10ESiVH

1 28
Download 28 pages 36.07 Kb
Page 5
Image 5
i n s t a l l a t i o n

i n s t a l l a t i o n

site INSTALLATION

d a n g e r

IMPROPER INSTALLATION,

ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.

d a n g e r

AVERTISSEMENT : UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICE OU UN ENTRETIEN NON CONFORME AUX NORMES PEUT CAUSER DES DOMMAGES À LA PROPRIÉTÉ, DES BLESSURES OU LA MORT.

LIRE ATTENTIVEMENT LES DIRECTIVES D’OPÉRATION ET D’ENTRETIEN AVANT DE FAIRE L’INSTALLATION, OU L’ENTRETIEN DE CET ÉQUIPEMENT.

installation codes & Standards

The following codes and standards are required for installation of this oven: air supply, electrical connections, water connections, and waste water discharge.

NOTE:

Where automatically operated appliances are vented through a ventilating hood or exhaust system equipped with a damper or with a power means of exhaust, provisions shall be made to allow the equipment to operate only when the damper is open to a position to properly vent the appliance and when the power means of exhaust is in operation.

in accordance with NFPA 54 commonwealth of massachusetts only.

ventilation requirements

A steam ventilation hood is mandatory for the operation of the oven. The ventilation hood must be installed in accordance with local building codes for the steam exhaust and must protrude 12-inches to 20-inches (300 to 500mm) over the front side of the oven. A grease filter must be located in the protruding area of the hood. Grease filters should be thoroughly cleaned on a regular basis following manufacturer's instruction. Ventilation hoods must ensure an adequate amount of incoming air during operation and must be operated whenever the combination oven/steamer is used in order to avoid the accumulation of condensation in the hood area.

sound pressure measurement

 

Sound Pressure Level dBA

 

 

 

Microphone Position

With Hood

Without

 

System

Hood System

 

Operating

Operating

 

 

 

Front

70

59

 

 

 

Right Side

69

58

 

 

 

Left Side

70

60

 

 

 

Rear

69

60

 

 

 

CT Express INSTALLATION MANUAL • 3..