Top/Back of unit

i n s t a l l a t i o n

electrical connection

note: where local codes and ce regulatory requirements apply, appliances must be connected to an electrical circuit that is protected by an external gFci outlet.

when required, recommended ground fault for combitherm ovens is an appropriately sized breaker with built-in 30ma ground fault protection.

Manual background danger

ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.

danger

To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.

Top/Back of unit

EQUIPOTENTIAL

GROUND SCREW

380-415V ONLYINCOMING ELECTRICAL TERMINALS APPLIES TO 208-240V & 380-415V UNITS CUSTOMER MUST SUPPLY CORD

L1 Manual background

L2 Manual background

L3Manual background

N Manual background

 

INTERNAL

Ground

GROUND STUD