TROU BL ES HOOTIN G - MANUAL | CONTROL | ||||
|
|
|
| ||
|
|
|
| ||
Error |
|
| Possible Cause | ||
Code | Description/Results | Service Required | |||
Air Sensor Fault (shorted) | Air sensor is shorted. | ||||
Air sensor defective? | |||||
|
| Inoperative Unit | |||
|
|
| Test air sensor by placing sensor in ice water bath32°F (0°C) and using an | ||
|
|
| ohmmeter set on the ohm scale. The readingshould be 100 ohms resistance. If it | ||
|
|
| is more than 2 ohms higher or lower, sensor needs to be replaced. If Ohm reading | ||
|
|
| is 100, replace display. If Ohm reading is not 100, replace sensor. | ||
Air Sensor Fault (open) | Air sensor is open or connection failure. | ||||
|
| Inoperative Unit | Air sensor defective? See above forair sensor test. | ||
Under temperature | Unit door closed? Door gasket need replacement? Preheat skipped? | ||||
| Oven will not reach set temperature | Unit overloaded or holding frozen product? Defective air sensor orprobe? | |||
| Defective solid state relay? Badwire connections or open heating cable? | ||||
|
|
| If none of the above, contact | ||
Over temperature | Unit has exceeded its maximum allowable set temperature by 25 degrees for at | ||||
least 3 minutes. Unit will shut down. | |||||
|
| Unit will shut down | |||
|
|
| Defective sensor or poor sensor connection? | ||
|
|
| Defective relay? | ||
|
|
| Shorted heater element? | ||
|
|
| If none of the above, contact | ||
Configuration error Inoperative Unit | Contact | ||||
or | EEPROM Error - Bad Checksum | Contact | |||
|
| ||||
| Inoperative Unit | Stuck button on control panel. Check buttons. | |||
Button shorted |
| ||||
Inoperative Control | If control is still inoperative, contact | ||||
|
| ||||
Input failure |
| Contact | |||
|
|
| |||
Power Failure |
| Press any key to acknowledge. | |||
|
|
| |||
|
|
|
|
|
|
|
| |
| This section is provided for the assistance of qualified techni cians only and is not intende d for use by |
| |
| untrained o r unauth orized serv ice personn el. If your |
| |
| following before calli ng you r Authoriz ed |
| |
| ☛ | Check the power flo w to the unit. Pl ug in outl et? Ci rcuit breaker sw itch at bac k of unit turned on? |
|
|
| Do not attempt to repa ir or serv ice the holding cabinet beyond thi s point. Contact Alto- Shaam® for the |
|
|
| nearest authorized service agent. Repairs made by any other serv ice agents without prior authorization |
|
|
| by |
|
|
|
|
|
DANGER
DIS CONNECT UNI T F ROM
POWER SOURCE B EFO RE
CLEANI NG OR SERVI CING.
CA UTI ON
THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.