31
MasterSwitch 100V – User Guide
31
Outlet Configuration (sPDUOutletConfig) OIDs
The sPDUOutletConfig OIDs consist of an sPDUOutletConfigTableSize read-only OID that defines the
number of outlets (always 8), as well as one set of identical OIDs for each outlet, each set consisting of:
qAn sPDUOutletConfigIndex read-only OID that identifies the outlet.
qAn sPDUOutletPowerOnTime OID that allows you to define how much time, if any, in seconds, the
outlet will delay providing output power when master power is newly applied:
-1 (for never power on automatically)
0 (no delay: power on with master)
15 (for 15-second delay)
30 (for 30-second delay)
45 (for 45-second delay)
60 (for 1-minute delay)
120 (for 2-minute delay)
300 (for 5-minute delay)
qAn sPDUOutletName OID that allows you to define an up to 20-character long device name for the
outlet.
Traps
The MasterSwitch can send eight different MasterSwitch-MIB traps and three MIB-II traps.
MasterSwitch-MIB Traps
The following table briefly identifies and describes the eight MasterSwitch-MIB traps.
MasterSwitch-MIB Trap Index Number - Description
outletOn 41 -The specified outlet has been turned on (if 0, all outlets have been turned on).
outletOff 42 -The specified outlet has been turned off (if 0, all outlets have been turned off).
outletReboot 43 -The specified outlet has been rebooted (if 0, all outlets have been rebooted).
configChangeSNMP 44 -The SNMP configuration has been changed.
configChangeOutlet 45 -The specified outlet has changed configuration (if 0, the master outlet has changed
configuration.
accessViolationConsole 46 -Three unsuccessful terminal console logins have occurred.
configViolationHTTP 47 -An unsuccessful HTTP login has occurred.
passwordChange 48 -The password for the MasterSwitch has changed.
MIB-II Traps
The following table briefly identifies and describes the three MIB-II traps.
MIB-II Traps Index Number - Description
coldStart 0 - The MasterSwitch has been turned on.
warmStart 1 - A MasterSwitch reinitialization has occurred.
snmpAuthenticationFailure 4 - An attempt to use SNMP to access the MasterSwitch, while using an incorrect
community name, has occurred.