Introduction

Table 4: Software program literature

Description

Manual #

Air Source Heat Pump with Electric Heat (Software Model 00)

OM 748

Water Source Heat Pump with Electric Heat (Software Model 02)

OM 749

Water Source Heat Pump without Electric Heat (Software Model 03)

 

DX Cooling with Electric Heat (Software Model 04)

OM 750

DX Cooling Only (Software Model 05)

OM 751

Electric Heat Only (Software Model 06)

OM 752

DX Cooling with Hydronic Heat - Valve Control (Software Model 07)

OM 753

DX Cooling with Hydronic Heat - F&BP Damper Control (Software Model 08)

 

2-Pipe Hydronic Heat Only - Valve Control (Software Model 09)

OM 754

2-Pipe Hydronic Heat Only - F&BP Damper Control (Software Model 10)

 

2-Pipe Chilled Water Cooling and Hot Water Heat - Valve Control (Software Model 11)

OM 755

2-Pipe Chilled Water Cooling and Hot Water Heat - F&BP Damper Control (Software

 

Model 12)

 

4-Pipe Chilled Water Cooling and Hydronic Heat - Valve Control (Software Model 13)

OM 756

4-Pipe Chilled Water Cooling and Hydronic Heat - F&BP Damper Control (Software

 

Model 14)

 

2-Pipe Chilled Water Cooling Only - Valve Control (Software Model 15)

OM 757

2-Pipe Chilled Water Cooling Only - F&BP Damper Control (Software Model 16)

 

2-Pipe Chilled Water Cooling with Electric Heat - Valve Control (Software Model 17)

OM 758

2-Pipe Chilled Water Cooling with Electric Heat - F&BP Damper Control (Software

 

Model 18)

 

NOTICE

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against detrimental interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause detrimental interference in which case users are required to correct the interference at their own expense. McQuay International disclaims any liability resulting from any interference or for the correction thereof.

WARNING

Electric shock hazard. Can cause personal injury or equipment damage.

This equipment must be properly grounded. Connections and service to the MicroTech II control panel must be performed only by personnel that are knowledgeable in the operation of the equipment being controlled.

CAUTION

Extreme temperature can damage system components.

The MicroTech II controller is designed to operate in ambient temperatures from -20°F to 125°F. It can be stored in ambient temperatures from -40°F to 140°F. It is designed to be stored and operated in relative humidity up to 95% (non-condensing).

CAUTION

Static sensitive components. A static discharge while handling electronic circuit boards can damage components.

Discharge any static electrical charge by touching the bare metal inside the main control panel before performing any service work. Never unplug any cables, circuit board terminal blocks, relay modules, or power plugs while power is applied to the panel.

4

McQuay OM 751

Page 4
Image 4