COMMERCIAL ELECTRIC WATER HEATER

SERVICE MANUAL

TABLE OF CONTENTS

INTRODUCTION

2

ELECTRONIC CONTROLS

41

Qualifications

2

CCB - Central Control Board

42

Service Warning

2

CCB Socket & Wiring Terminal Identification

43

Tools Required

3

CCB Enable Disable Circuit(s) Test

45

INSTALLATION CONSIDERATIONS

4

Checking Power And Ground To The CCB

46

Closed Water Systems

4

UIM - User Interface Module

47

Thermal Expansion

4

ELECTRONIC CONTROL SYSTEM

48

Electrical Requirements

5

Control System Features

48

PRE SERVICE CHECKS

6

Control System Navigation

48

Wiring Connections

6

The Desktop Screen

49

Service Precautions

5

Status Icons

50

WATER HEATER CONSTRUCTION

7

Operating States

51

Surface Mount Control Models

8

Control System Menus

51

Electronic Control Models

9

Temperatures Menu

52

OPERATION & SERVICE

10

Temperature Settings

53

Principles of Electricity

10

Heater Status Menu

54

Single And Three Phase Power

12

Economy Mode Setup Menu

55

Checking Single Phase Power

13

Setpoint Adjustment Value

56

Checking Three Phase Power

14

Time Clock Settings

57

Phase Conversions - Surface Mount Control Models

15

Daily Operating Mode Settings

58

Phase Conversions - Electronic Control Models

16

Alarm Output Setup Menu

59

Fuses

17

Display Settings Menu

60

Surface Mount Thermostats

18

Heater Information Menu

61

Thermostat & ECO Test

19

Current Fault/Alert Menu

62

Heating Elements

20

Fault History Menu

62

Heating Element Construction

20

Fault Occurrence Menu

62

Heating Element Amperage Test

23

Restore Factory Defaults Menu

63

Heating Element Voltage Test

24

Factory Default User Settings

63

Heating Element Resistance & Ground Test

25

TROUBLESHOOTING

64

Replacing Heating Elements

26

Common Service Problems

64

Element Sensors

27

Surface Mount Control Models

64

Element Sensor Operation

28

Electronic Control Models

65

Contactors

29

Fault Conditions

65

Contactor Configurations

30

Alert Conditions

65

Contactor Inspection

31

Resetting The Control System

65

Contactor Coil Voltage - At Contactor

32

Control System Unresponsive

65

Contactor Coil Voltage - At CCB

33

UIM Display Is Blank

65

Transformers

34

UIM Is Inoperable

66

120 VAC Control Circuit Transformer Wiring

34

Heating Cycle Disabled

66

120 VAC Control Circuit Transformer Test

35

Fault & Alert Messages

67

24 VAC Transformer Test

36

No Current Detected

67

Immersion Temperature Probes

37

Temp Probe Open

68

Temperature Sensor Resistance Test

38

Temp Probe Short

68

Temperature Sensor DC Voltage Test

39

Energy Cut Out (ECO)

69

ECO Continuity Test

39

 

 

ECO Voltage Test

40

 

 

Page 3
Image 3
American Water Heater STCE3-52/80/119, ITCE3-52/80/119 Commercial Electric Water Heater, Table Of Contents, Service Manual