American Water Heater STCE3-52/80/119 manual CCB Socket & Wiring Terminal Identification

Models: ITCE3-52/80/119 COMMERCIAL ELECTRIC WATER HEATERS STCE3-52/80/119

1 76
Download 76 pages 3.39 Kb
Page 45
Image 45
CCB Socket & Wiring Terminal Identification

ELECTRONIC CONTROLS

CCB Socket & Wiring Terminal Identification

Refer to the illustration on page 42 for physical location of the sockets and wiring terminals.

J1 Socket - Transformer

PIN #

DESCRIPTION

1120 VAC hot to transformer

2Not used

3120 VAC neutral to transformer

424 VAC out from transformer

524 VAC out from transformer

J2 Socket - 120 VAC Power Supply

PIN #

DESCRIPTION

1120 VAC hot

2Earth Ground

3120 VAC neutral

J3 Wiring Terminals - Alarm Output Relay (see page 59)

TERMINAL

DESCRIPTION

 

 

N. O.

Dry Contact Output - Normally Open Terminal Alarm Output Relay

N. C.

Dry Contact Output - Normally Closed Terminal Alarm Output Relay

COM

Dry Contact Output - Common Terminal Alarm Output Relay

J4 Wiring Terminals - Contactor Coils

TERMINAL

DESCRIPTION

 

 

OUT 1

120 VAC hot to Heating Element Bank 1 Contactor Coils

OUT 2

120 VAC hot to Heating Element Bank 2 Contactor Coils

OUT 3

120 VAC hot to Heating Element Bank 3 Contactor Coils

J5 Socket - Immersion Temperature Probe/ECO

PIN #

DESCRIPTION

1ECO (energy cut out) 120 VAC hot out (red wire)

2Temperature probe (thermistor) +5.0 VDC (black wire)

3Temperature probe (thermistor) -5.0 VDC (black wire)

4ECO (energy cut out) 120 VAC return (red wire)

J6 Socket - Not Used

Servicing should only be performed by a Qualified Service Agent