American Water Heater ITCE3-52/80/119 Uim - User Interface Module, UIM Circuit Board Back, Screen

Models: ITCE3-52/80/119 COMMERCIAL ELECTRIC WATER HEATERS STCE3-52/80/119

1 76
Download 76 pages 3.39 Kb
Page 49
Image 49
UIM - USER INTERFACE MODULE

ELECTRONIC CONTROLS

UIM - USER INTERFACE MODULE

UIM Components

The UIM’s major components include a Circuit Board with LCD display and a Button Pad Overlay which contains the five user input buttons.

Service Notes - Button Pad Ribbon Cable

The Ribbon Cable that connects the Button Pad Overlay to the UIM Circuit Board must be plugged in exactly as shown in the images below; with the metal crimp connections visible on the plug end and the UIM Circuit Board back facing out. There are six pins on this Ribbon cable socket, Ensure all six pins are inserted into the Ribbon Cable plug whenever removing or installing the UIM or Button Pad Overlay.

Failure to connect this Ribbon cable exactly as shown when servicing will render the User Input Buttons inoperable. This should be checked whenever the nature of the service complaint is an inoperable or unresponsive controller or UIM.

Button Pad Overlay

Ensure Ribbon Cable Plug is inserted exactly as shown.

UIM Circuit Board Back

J2 Socket - CCB

J3 Socket - Button Pad

Communication

Communication

Ribbon Cable To

Button Pad

 

LCD

UIM Circuit Board Front

Screen

 

Servicing should only be performed by a Qualified Service Agent

47

Page 49
Image 49
American Water Heater ITCE3-52/80/119 Uim - User Interface Module, UIM Circuit Board Back, UIM Circuit Board Front, Screen