Temperature Sensor Resistance Test

OPERATION & SERVICE

Temperature Sensor Resistance Test

1Secure power to the water heater at the main breaker or disconnect switch.

2Unplug the J5 plug from the CCB circuit board - see page 42 for location.

3Using an ohm meter: set the ohm meter range to a scale above 30,000 ohms initially.

4Touch the ohm meter probes between the two middle pins (black wires) of the J5 plug end as shown in the image below. Compare the measured resistance value (ohms) to the values given in the resistance data table below. Temperature probes are very reliable and should only be replaced when:

The resistance test indicates an “open” (infinite resistance) or a “direct short” (no resistance) circuit.

The nature of the service problem is temperature control and the resistance readings are considerably (25% or more) different than the values in the table here at the given temperature.

Checking Temperature Sensor Resistance

Temperature Sensor Resistance Data

WATER TEMPERATURE

RESISTANCE

Celsius

Fahrenheit

IN OHMS

 

 

 

 

40°

26,435

 

 

 

21°

70°

11,974

 

 

 

38°

100°

5,862

 

 

 

49°

120°

3,780

 

 

 

55°

130°

3,066

 

 

 

60°

140°

2,503

 

 

 

71°

160°

1,698

 

 

 

82°

180°

1,177

 

 

 

Servicing should only be performed by a Qualified Service Agent