RESTORE FACTORY DEFAULTS MENU

RESTORE FACTORY DEFAULTS MENU

This control system menu allows the user to restore most of the control system’s user settings to their factory default settings. User settings in the Alarm Output Setup and

Display Settings menus are unaffected by executing Restore Factory Defaults.

Restore Factory Defaults

ACTION

DISPLAY

From the Main Menu use the Up/Down buttons to select (highlight in black) the “Restore Factory Defaults” menu.

Press the Operational Button underneath “SELECT.” The Restore Factory Defaults menu will be displayed.

From the Restore Factory Defaults menu press the Operational Button underneath “YES.” The display will show text confirming the factory default settings have been restored.

Press the Operational Button underneath “BACK” to exit the Restore Factory Defaults menu.

Factory Default User Settings

TEMPERATURES MENU

DEFAULT SETTING

ADJUSTABLE RANGE

 

 

 

Operating Set Point

120°F (49°C)

90ºF to 190ºF (32°C to 88°C)

 

 

 

Differential Settings

2°F (1°C)

1°F to 20°F (1°C to 11°C)

 

 

 

Tank Probe Offset

0°F (0°C)

-5°F to +5°F (-3°C to +3°C)

 

 

 

ECONOMY MODE SETUP MENU

DEFAULT SETTING

ADJUSTABLE RANGE

 

 

 

Setpoint Adjustment

20°F (11°C)

2°F to 50°F (1°C to 28°C)

 

 

 

Daily Operating Mode

Normal Operation All Day

See page 55

 

 

 

ALARM OUTPUT SETUP MENU

DEFAULT SETTING

ADJUSTABLE RANGE

 

 

 

Alarm Output Function

Disabled

See page 59

 

 

 

Alarm SP

100 (38°C)

90ºF to 190ºF (32°C to 88°C)

 

 

 

DISPLAY SETTINGS MENU

DEFAULT SETTING

ADJUSTABLE RANGE

 

 

 

Temperature Units

°Fahrenheit

°Fahrenheit or °Celsius

 

 

 

Backlight Delay

10 Seconds

Always off/on, 10, 30, 60 Sec

 

 

 

Contrast

30%

20% to 100%

 

 

 