Notes:

1.You should perform a media calibration after installation and when changing to a different type or size of media.

2.Before calibration, you must load the media and ribbon properly and move the label sensor to the correct position avoiding holes.

3.After calibration the printer saves parameters to FLASH. Without correct calibration gap detection is easily lost during printing especially for small labels (less than 1.5 inches in height).

4.After self-test, the printer is in dump mode. For normal operation, you must press CANCEL to restart the printer.

LCD Display

The FM 4600 PLUS Series models have a LCD that shows:

printer status

printer settings

input data from a keyboard or barcode reader

The first parameter is either 203 or 300, which stands for the print resolution. The second parameter indicates the emulation (printer language), PAL/PPLZ, PPLA, or PPLB.

After power-on, the LCD displays the following message as examples:

FM 4602 PLUS Series

(203, PAL/PPLZ)

FM 4603 PLUS Series

(300, PAL/PPLZ)

If a keyboard is plugged in, the display shows:

FM 4602 PLUS Series

(203, PAL/PPLZ)

<ESC> FOR KEYBD