AMT Datasouth 4600 Feature, Parameter, Factory Default, Remarks, Peeler, Installed, Counting

Models: 4600

1 91
Download 91 pages 37.19 Kb
Page 15
Image 15

Feature

Parameter

Factory Default

Remarks

PEELER

YES

NO

 

INSTALLED

NO

 

 

COUNTING

UP

DOWN

 

 

DOWN

 

 

MEDIA

GAP

GAP

Select for media

SENSOR TYPE

BLACK BAR

 

characteristics. Once

 

 

 

changed make sure to

 

 

 

calibrate before printing.

PRESENT

.0~040”

.87”

Appears only when

DISTANCE

 

 

BACKFEED enabled.

ABS

0~30

0

Setting darkness

DARKNESS

 

 

 

TRIM

-30~30

0

Fine-tuning darkness

DARKNESS

 

 

 

BAUD RATE

600 / 1200 / 2400/

9600

 

(RS232)

4800 / 9600 /

 

 

 

19200 /NONE

 

 

PARITY

NONE

NONE

 

(RS232)

EVEN

 

 

 

ODD

 

 

LENGTH

8 DATA BITS

8 DATA BITS

 

(RS232)

7 DATA BITS

 

 

CLEAR FLASH

YES/NO

NO

 

 

PRINTERS WITH ETHERNET

DHCP

ENABLE

ENABLE

 

 

DISABLE

 

 

IP ADDRESS

###.###.###.###

 

 

SUBNET MASK

###.###.###.###

 

 

DEFAULT

###.###.###.###

 

 

GATEWAY

 

 

 

MAC

####.####.####

 

 

ADDRESS

 

 

 

15

Page 15
Image 15