Chapter 3: Mount the Device

You can mount the P333T-PWR in a rack.

The P333T-PWR chassis fits in most standard 19-inch racks. It is 2U (3.5”, 88 mm) high.

Before you Install the P333T-PWR in a Rack

Disconnect all cables from the unit before proceeding with the rack installation.

When installing the P333T-PWR in a rack, ensure that the equipment is positioned such that it will not cause the rack to become unstable or tip over.

Ensure that the combination of equipment in the rack will not cause an overload or overcurrent condition on the power strip being used and/or the customer's branch circuit.

The P333T-PWR units weigh a maximum of 15 pounds (6.8 kg). Be careful when installing or removing the P333T-PWR product from the rack.

If a power strip is being used in the rack, ensure that it has a reliable earth connection. If the P333T-PWR equipment will be plugged directly into a wall outlet, ensure that there is a reliable ground connection at the outlet.

Ensure that the internal rack ambient temperature is within the operating specification limits of the P333T-PWR.

Ventilation for the P333T-PWR is from side to side. Ensure that there is adequate space on each side of the P333T-PWR equipment when installed in the rack to allow sufficient airflow.

Place the P333T-PWR in the rack as follows:

1.Snap open the hinged ends of the unit’s front panel to reveal the screw holes. Refer to Figure 2 and Figure 3.

Figure 2: Closed hinged end

P333R

51

52

53

54

55

56

57

58

1

2

3

4

5

6

7

8

9

10

11 12

 

 

 

 

 

 

 

 

 

 

 

EXPANSION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLOT

 

 

62

 

 

 

 

 

 

15

 

17

 

 

 

 

 

23

24

 

 

 

 

 

 

 

 

 

 

 

59

60

61

63 64

65

66

13

14

16

18

19 20

21 22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIV

 

 

LNK COL

Tx

Rx

FDX

FC Hspd

LAG

 

 

 

 

ROUTSYS

OPR

PWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAG

 

 

 

LAG

 

 

 

LAG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONSOLE

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

14

15

16

17

18

19

20

21

22

23

24

Figure notes:

1.Closed hinged end

Issue 1 September 2005 17

Page 19
Image 19
Andis Company P333T-PWR quick start Mount the Device, Closed hinged end