![](/images/backgrounds/108845/108845-3630x1.png)
TROUBLESHOOTING
PROBLEM | PROBABLE CAUSE | CORRECTION | ||
Unit throws snow | 1. | Shear bolts broken. | 1. | Replace shear bolts (see Shear |
poorly or does not |
|
|
| |
throw snow. |
|
|
|
|
| 2. | Attachment clutch/brake | 2. | Adjust attachment clutch/brake |
|
| not adjusted properly. |
| (see Attachment Clutch/Brake |
|
|
|
| Adjustment on page 25). |
| 3. | Auger is frozen in place. | 3. | Move unit to a warm place to |
|
|
|
| thaw. |
| 4. | Ice or debris is obstructing | 4. | Move PTO and key switches to |
|
| auger. |
| OFF position. Remove key from |
|
|
|
| switch. Clear blockage from |
|
|
|
| auger or chute (see Snow Clean- |
|
|
|
| |
| 5. | Attachment drive belt | 5. | Adjust or replace attachment |
|
| slipping, worn or damaged. |
| drive belt (see Attachment |
|
|
|
| Clutch/Brake Adjustment on |
|
|
|
| page 25). |
Controller displays | 1. | A trouble code has been | Perform the suggested correction. If | |
flashing red light |
| set in the electrical system: | trouble code resumes contact your | |
under the cover. |
| ____ = long flash | Ariens Dealer. | |
|
| • = short flash |
|
|
Controller |
|
| |
Code: |
|
| |
1. | ____ •____• | 1. | Turn key to OFF position, allow |
| (Motor Coil Overheated) |
| unit to fully cool before resuming. |
2. | ____ • •____• • | 2. | Contact your Ariens Dealer. |
| (Motor Position Error) |
|
|
3. | ____ • • •____• • • | 3. | Turn key to OFF position, allow |
| (Controller Overheated) |
| unit to fully cool before resuming. |
4. | ____ • • • •____• • • • | 4. | Charge batteries (see Low |
| (Low System Voltage) |
|
5.____ ____• •____ ____• • 5. Move PTO and key switches to
(Stall Mode) | OFF position. Remove key from |
| switch. Clear blockage from |
| auger or chute (see Snow Clean- |
| |
| NOTE: Unit must be OFF for a |
| minimum of 30 seconds before |
| resuming. |
GB - 30